Replacing a T18 or T35 roof: checks before changing the profile
Switching from T18 to T35 is not simply a matter of choosing a trapezoidal sheet with a higher profile. It can change the cover width, the number of sheets and the detailing at the terminations. In a renovation, the existing supports must also be checked. Below we compare actual profile types and show how to go from their dimensions to the cutting plan and the complete order. The number in the name usually indicates the nominal profile height in millimetres. T35 has a higher rib than T18. However, this does not mean that the name alone determines the load-bearing capacity. The assessment requires the full geometry, the steel thickness and grade, and the support conditions.