Does rigid EPS insulation reduce footstep noise effectively?

At a glance

Rigid EPS is used primarily for thermal insulation and for load-bearing applications. It should not be confused with acoustic EPS T. Reducing impact sound requires a resilient layer and a floor isolated from walls and structure. The result depends on the entire floor structure, the screed, the connections and the workmanship. The thickness of ordinary polystyrene alone does not guarantee quiet. A footstep, a chair being moved or an object being dropped sets the floor vibrating. The energy can be transmitted through the floor structure and connections to other rooms. This is a different phenomenon from speech heard through a partition. A material that improves one type of insulation performance does not have to be equally effective in the other range, so it is worth establishing which kind of noise is the problem.

Two white polystyrene boards of different thicknesses, with visible granule structure.

How are impact sounds produced?

For impact noise from footsteps, it is important to limit the transmission of vibrations from the screed to the structure. A properly designed floating floor serves this purpose. Its resilient layer should have properties matched to the mass of the screed and the loads. It is not enough to insert any soft material. Excessive compliance can in turn impair the stability of the floor.

How does EPS T differ?

EPS T is a grade prepared for acoustic applications, including under floating screeds. The documentation specifies dynamic stiffness SD and compressibility CP. Standard hard EPS for floors is selected primarily on the basis of thermal and mechanical properties. Even if both products have a similar colour and format, they are not interchangeable on that account.

In EPS T, you may come across a thickness designation, for example 33/30 mm. It refers to specific measurement conditions before and after loading, not to two bonded layers. Such a board is a component of a system. Its permissible load and the way it is laid must be read from the documentation, rather than derived from the name acoustic alone.

Why does greater hardness not mean better acoustics?

A board resistant to compression can support a screed well, but it does not necessarily decouple vibrations effectively. The CS(10) parameter does not describe dynamic stiffness. Two materials therefore cannot be compared acoustically on the basis of the EPS100 and EPS200 figures. A higher compression class corresponds to a different task than reducing the transmission of footfall noise.

A lower lambda also does not prove better sound attenuation. A graphite board can have very good thermal insulation properties and not be intended as a resilient layer. When buying, it is worth separating the requirements relating to heat and to sound. If both functions are needed, the design can provide for a suitable combination of EPS T and additional floor insulation.

What can impair the performance of the resilient layer?

The screed should not rigidly touch walls, columns and other vertical elements if the system is to be floating. A hard mortar bridge can transmit vibrations despite a good board. That is why the perimeter strip and the details at thresholds are just as important as the floor field. It is worth checking them before pouring the screed, when repair is still easy.

Bridges can also occur at pipes, at a damaged separating layer or where the finishing has been poorly executed. The skirting board should not connect the layers in a way that conflicts with the design. Once the work is finished, hidden joints are difficult to assess. Photographs and inspection of the successive stages are more useful than later searching for the cause of the noise solely at the floor surface.

Can the result be given in decibels?

The declared improvement in insulation or the test result relates to a specific assembly and specific conditions. It is not a guarantee of an identical effect on every floor structure. The mass and type of construction, the screed, the side connections and the workmanship all matter. A reliable result for any floor in an existing house cannot be calculated from the SD or CP value alone.

During renovation, the existing floor structure and the type of noise must first be identified. An underlay beneath the panels can improve certain characteristics, but it is not the same as a full floating floor. Replacing the finish does not automatically remove rigid connections between the screed and the wall. If the desired result is significant, calculations or selection based on a proven solution are needed.

How do you choose the right solution for a home?

It is worth determining whether the floor separates flats, rooms within one house, or the interior from a cold cellar. Thermal and acoustic requirements and loads are then established. Only then are the board and screed build-up selected. Additional layers of EPS T should not be added without confirmation, because manufacturers often intend it to be laid in a single layer.

The order should specify the parameters and the exact thickness. On delivery, it must be checked whether an acoustic board has been supplied rather than ordinary EPS of a similar appearance. A well-chosen material helps to reduce impact sound, but it works together with correct separation of the screed. It is the execution of the whole system that determines whether its properties are utilised.

Acoustic EPS T polystyrene is offered by Austrotherm, Polstyr, Styrmann and Justyr, among others. The installation requirements and permissible loads depend on the variant.

7 branches. Materials closer to your project.

Izoprofil.net map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E
  • BŁONIE — ul. Sochaczewska 138A
  • RADOM — ul. Grobickiego 8
  • ŁÓDŹ — Natolin 8
  • OLSZTYN — Barczewo, ul. Prosta 9
  • WROCŁAW — ul. Jerzmanowska 10C
  • GORZÓW WLKP. — ul. Zielona 33/34

Check prices and availability: +48 500 409 109

Free quote

Materials for your project